Electronic signatures under 21 CFR Part 11: what each signature must carry
What 21 CFR Part 11 and EU GMP Annex 11 ask of an electronic signature, in plain language: what it shows, its link to the record and its two components.
An electronic signature in a GMP system is not a picture of someone’s handwriting pasted onto a page. It is an act, recorded by the system, that has to mean exactly what an ink signature means: this person, at this moment, takes responsibility for this record, in this capacity. 21 CFR Part 11 sets out what that takes. This guide walks through it in plain language.
Where Part 11 applies
Part 11 is the US FDA regulation on electronic records and electronic signatures. It applies to records that other FDA regulations require you to keep (the “predicate rules”, such as the drug GMP regulations in 21 CFR Parts 210 and 211) when you keep them electronically, and to electronic signatures used in place of handwritten ones on those records. If you manufacture for the US market, or for a customer who does, it applies to you. In Europe the equivalent expectations are in EU GMP Annex 11, and many other inspectorates follow one or both.
The FDA’s 2003 guidance on the scope and application of Part 11 narrowed how some requirements are enforced. The requirements for electronic signatures were not among them.
What every signature must show: §11.50
A signed electronic record must show three things about each signature, both on screen and on any printout:
- The printed name of the signer. Not a user ID that someone has to look up.
- The date and time it was signed. Taken from the system, not typed.
- The meaning of the signature, such as review, approval, responsibility or authorship.
The meaning is the part most often missing. “Signed by A. Desai” says who; it does not say whether she reviewed the record, approved it or wrote it, and those carry different responsibilities.
The signature must stay with its record: §11.70
Signatures must be linked to their records so that they cannot be removed, copied or transferred to falsify another record. In practice this means the signature is bound to the exact content that was signed. If the record changes afterwards, the old signature must not silently carry over to the new version.
One person, one signature: §11.100
Each electronic signature must be unique to one individual and never reused by or reassigned to anyone else. The organisation must verify a person’s identity before it gives them one. Before using electronic signatures, the company also certifies to the FDA in writing that it regards them as the legally binding equivalent of handwritten signatures. That letter is the manufacturer’s job, not the software supplier’s.
Two components: §11.200
A signature that is not biometric must use at least two distinct identification components, such as an identification code and a password. When a person signs several times in one continuous session, the first signing uses all the components and later ones at least one component that only that person can use. Outside a continuous session, every signing uses all of them.
The section also requires that a signature cannot be used by anyone other than its owner without two or more people colluding. That is why the way passwords and PINs are administered matters as much as the signing screen itself.
Passwords and codes: §11.300
Controls over identification codes and passwords include keeping each combination unique, checking and revising them periodically, handling lost or compromised credentials, and safeguards that prevent unauthorised use and detect attempts, reporting them to management where appropriate.
The audit trail: §11.10(e)
Signatures sit inside a wider requirement for secure, computer-generated, time-stamped audit trails that independently record when operators create, modify or delete records. A change must not obscure what was recorded before, and the audit trail must be kept as long as the records themselves and be available for inspection.
The same idea in EU GMP Annex 11
Annex 11, clause 14, says electronic signatures are expected to have the same impact as handwritten ones within the company, to be permanently linked to their record, and to include the time and date they were applied. Clause 9 asks for an audit trail of GMP-relevant changes and deletions, with the reason documented.
Eight questions to ask of any system
- Does every signature show the signer’s full name, the date and time, and its meaning, on screen and on prints?
- Is the signature bound to the version of the record that was signed?
- Does signing need two components every time outside a continuous session?
- Can an administrator set, reset or see a user’s signing credential? If so, could they sign as that person?
- Does the system stop a person from approving their own work?
- Is a reason recorded for every change, and is the old value kept?
- Can the audit trail be switched off or edited, by anyone?
- Does an account lock after repeated failed attempts?
How Pharma-ETA handles it
In Pharma-ETA, each signature records its meaning and a reason, and needs both the person’s password and a separate signing PIN. Only the owner can set their PIN; an administrator cannot, so nobody can sign as someone else. Signatures are bound to the record version they sign, approvals by the same person who did the work are refused, and the audit trail is always on and hash-chained so that alteration shows. See the compliance page for the control-by-control mapping.
This article summarises the regulations for general information. It is not legal or regulatory advice; rely on the published texts and your own procedures.